Development and characterization of an implantable biosensor for telemetric monitoring of ethanol in the brain of freely moving rats

Rocchitta, Gaia Giovanna Maria and Secchi, Ottavio and Alvau, Maria Domenica and Migheli, Rossana and Calia, Giovanna Maria and Bazzu, Gianfranco and Farina, Donatella and Desole, Maria Speranza and O'Neill, Robert D. and Serra, Pier Andrea (2012) Development and characterization of an implantable biosensor for telemetric monitoring of ethanol in the brain of freely moving rats. Analytical Chemistry, Vol. 84 (16), p. 7072-7079. eISSN 1520-6882. Article.

Full text not available from this repository.

DOI: 10.1021/ac301253h

Abstract

Ethanol is one of the most widespread psychotropic agents in western society. While its psychoactive effects are mainly associated with GABAergic and glutamatergic systems, the positive reinforcing properties of ethanol are related to activation of mesolimbic dopaminergic pathways resulting in a release of dopamine in the nucleus accumbens. Given these neurobiological implications, the detection of ethanol in brain extracellular fluid (ECF) is of great importance. In this study, we describe the development and characterization of an implantable biosensor for the amperometric detection of brain ethanol in real time. Ten different designs were characterized in vitro in terms of Michaelis–Menten kinetics (VMAX and KM), sensitivity (linear region slope, limit of detection (LOD), and limit of quantification (LOQ)), and electroactive interference blocking. The same parameters were monitored in selected designs up to 28 days after fabrication in order to quantify their stability. Finally, the best performing biosensor design was selected for implantation in the nucleus accumbens and coupled with a previously developed telemetric device for the real-time monitoring of ethanol in freely moving, untethered rats. Ethanol was then administered systemically to animals, either alone or in combination with ranitidine (an alcohol dehydrogenase inhibitor) while the biosensor signal was continuously recorded. The implanted biosensor, integrated in the low-cost telemetry system, was demonstrated to be a reliable device for the short-time monitoring of exogenous ethanol in brain ECF and represents a new generation of analytical tools for studying ethanol toxicokinetics and the effect of drugs on brain ethanol levels.

Item Type:Article
ID Code:8793
Status:Published
Refereed:Yes
Uncontrolled Keywords:Ethanol, nucleus accumbens, GABA
Subjects:Area 05 - Scienze biologiche > BIO/14 Farmacologia
Divisions:001 Università di Sassari > 01-a Nuovi Dipartimenti dal 2012 > Medicina Clinica e Sperimentale
Publisher:American Chemical Society
eISSN:1520-6882
Deposited On:13 Mar 2013 11:33

I documenti depositati in UnissResearch sono protetti dalle leggi che regolano il diritto d'autore

Repository Staff Only: item control page