UnissResearch

Logo Universitàegli studi di Sassari
titoli, abstracts, parole chiave >>>
Reconstruction of skeletal movement using skin markers: comparative assessment of bone pose estimators

Cereatti, Andrea and Della Croce, Ugo and Cappozzo, Aurelio (2006) Reconstruction of skeletal movement using skin markers: comparative assessment of bone pose estimators. Journal of NeuroEngineering and Rehabilitation, Vol. 3 (7), p. 1-12. ISSN 1743-0003. Article.

[img]
Preview
Full text disponibile come PDF Richiede visualizzatore di PDF come GSview, Xpdf o Adobe Acrobat Reader
Available under License Creative Commons Attribution.

634Kb

DOI: 10.1186/1743-0003-3-7

Abstract

Background: The assessment of the accuracy of the pose estimation of human bones and consequent joint kinematics is of primary relevance in human movement analysis. This study evaluated the performance of selected pose estimators in reducing the effects of instrumental errors, soft tissue artifacts and anatomical landmark mislocations occurring at the thigh on the determination of the knee kinematics. Methods: The pattern of a typical knee flexion-extension during a gait cycle was fed into a knee model which generated a six-components knee kinematics and relevant marker trajectories. The marker trajectories were corrupted with both instrumental noise and soft tissue artifacts. Two different cluster configurations (4 and 12-marker cluster) were investigated. Four selected pose estimators, a Geometrical method, a SVD-based method, and the Pointer Cluster Technique in the optimized and non optimized version, were analyzed. The estimated knee kinematics were compared to the nominal kinematics in order to evaluate the accuracy of the selected pose estimators. Results: Results have shown that optimal pose estimators perform better than traditional geometric pose estimators when soft tissue artifacts are present. The use of redundant markers improved in some cases the estimation of the dynamics of the kinematics patterns, while it does not reduce the offsets from the nominal kinematics curves. Overall, the best performance was obtained by the SVD-based pose estimator, while the performance of the PCT pose estimator in its optimal version was not satisfactory. However, the knee kinematics errors reached 5 deg for rotations and 10 mm for translations). Conclusion: Given the favorable experimental conditions of this study (soft tissue artifacts determined from a young, healthy and non overweight subject), the errors found in estimating the knee kinematics have to be considered unsatisfactory even if the best performing pose estimator is used. Therefore, it is the authors' opinion that the movement analysis research community should make additional efforts in the search of more subject specific error models to increase the accuracy of joint kinematics estimations.

Item Type:Article
ID Code:81
Status:Published
Refereed:Yes
Uncontrolled Keywords:Knee model, noisy movement, kinematics, soft tissue artifacts, Geometrical method, SVD-based method, Pointer Cluster Technique
Subjects:Area 09 - Ingegneria industriale e dell'informazione > ING-INF/06 Bioingegneria elettronica e informatica
Divisions:001 Università di Sassari > 01 Dipartimenti > Scienze biomediche
Publisher:BioMed Central
ISSN:1743-0003
Additional Information:Open Access
Deposited On:18 Aug 2009 10:01

I documenti depositati in UnissResearch sono protetti dalle leggi che regolano il diritto d'autore

Repository Staff Only: item control page