UnissResearch

Logo Universitàegli studi di Sassari
titoli, abstracts, parole chiave >>>
99mTc-tetrofosmin SPET in the detection of both primary breast cancer and axillary lymph node metastasis

Spanu, Angela and Dettori, Giuseppe Lorenzo and Nuvoli, Susanna Maria Francesca and Porcu, Alberto and Falchi, Antonio and Cottu, Pierina and Solinas, Maria E. and Scanu, Antonio Mario and Chessa, Francesca and Madeddu, Giuseppe (2001) 99mTc-tetrofosmin SPET in the detection of both primary breast cancer and axillary lymph node metastasis. European Journal of Nuclear Medicine and Molecular Imaging, Vol. 28 (12), p. 1781-1794. eISSN 1619-7089. Article.

Full text not available from this repository.

DOI: 10.1007/s00259-001-0657-5

Abstract

The aim of this study was to evaluate the usefulness of 99mTc-tetrofosmin single-photon emission tomography (SPET) in the detection of both primary breast cancer and axillary lymph node metastasis. We studied 192 consecutive patients in whom primary breast cancer was suspected on the basis of mammography and/or physical examination. After intravenous injection of 740 MBq 99mTc-tetrofosmin, both planar and SPET scintimammography was performed in all patients using a rectangular dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators. In 175 patients with breast cancer at histology, the per-lesion overall sensitivity of SPET and planar imaging for the detection of breast cancer was 95.8% and 75.9% (P<0.0005), respectively. The sensitivity of SPET and planar imaging was, respectively, 96.5% and 79.5% in palpable (P<0.0005) and 90% and 45% in non-palpable lesions (P<0.01). With regard to lesion size, the sensitivity of SPET and planar imaging was, respectively, 90.5% and 45.2% in lesions h10 mm (P<0.0005), 95.3% and 81.4% in lesions of 11-20 mm (P<0.005), 100% and 84.6% in lesions of 21-30 mm (P<0.05) and 100% and 95.8% in lesions >30 mm (P>0.05). In the remaining 17 patients with benign mammary lesions at histology, per-lesion overall specificity of SPET and planar imaging was 76.2% and 85.7% (P>0.05), respectively. Neither SPET nor planar imaging showed false-positive results in non-palpable lesions or in those h10 mm. In 173 breast cancer patients submitted to axillary lymph node dissection (ALND), per-axilla overall sensitivity of SPET and planar imaging in the detection of axillary lymph node metastasis was 93% and 52.3% (P<0.0005), respectively. The sensitivity of SPET and planar imaging was, respectively, 100% and 82.6% in palpable nodes (P>0.05), 90.5% and 41.3% in non-palpable nodes (P<0.0005), 92.8% and 35.7% in the presence of h3 nodes (P<0.0005) and 93.2% and 68.2% in the presence of >3 nodes (P6lt;0.005). The specificity of SPET and planar imaging was 91% and 100% (P<0.05), respectively. 99mTc-tetrofosmin SPET appears to be a reliable method for the detection of both primary BC and axillary lymph node metastasis, and its diagnostic accuracy exceeds that of 99mTc-tetrofosmin planar scintimammography. The use of SPET is particularly important in the identification of small non-palpable primary carcinomas and metastatic axillae with ≤3 non-palpable lymph nodes. More extensive use of SPET appears warranted in the management of breast cancer patients.

Item Type:Article
ID Code:7788
Status:Published
Refereed:Yes
Uncontrolled Keywords:99mTc-tetrofosmin, SPET, breast cancer, axillary lymph node metastasis
Subjects:Area 06 - Scienze mediche > MED/36 Diagnostica per immagini e radioterapia
Area 06 - Scienze mediche > MED/18 Chirurgia generale
Divisions:001 Università di Sassari > 01 Dipartimenti > Medicina clinica, sperimentale e oncologica
Publisher:Springer Berlin / Heidelberg
eISSN:1619-7089
Deposited On:17 Jul 2012 12:28

I documenti depositati in UnissResearch sono protetti dalle leggi che regolano il diritto d'autore

Repository Staff Only: item control page