titoli, abstracts, parole chiave >>>
The Role of planar scintimammography with high-resolution dedicated breast camera in the diagnosis of primary breast cancer

Spanu, Angela and Chessa, Francesca and Meloni, Giovanni Battista and Sanna, Daniela and Cottu, Pierina and Manca, Alessandra and Nuvoli, Susanna Maria Francesca and Madeddu, Giuseppe (2008) The Role of planar scintimammography with high-resolution dedicated breast camera in the diagnosis of primary breast cancer. Clinical Nuclear Medicine, Vol. 33 (11), p. 739-742. ISSN 0363-9762. eISSN 1536-0229. Article.

Full text not available from this repository.

DOI: 10.1097/RLU.0b013e318187ee75

Alternative URLs:

Abstract

Planar scintimammography (SM) acquired with a conventional γ camera has proved a useful complementary tool to mammography (Mx) in breast cancer (BC) diagnosis, but with unsatisfactory sensitivity in small size carcinomas. In this study we assessed the role of planar SM with a high-resolution dedicated breast camera (DBC) in BC diagnosis, comparing the results with those of Mx.
A consecutive series of 145 patients scheduled for biopsy for suspected BC underwent Tc-99m tetrofosmin planar SM using a newly developed DBC. Scintigraphic data were compared with Mx findings and correlated to histology.
Histopathologic analysis revealed 165 lesions: 143 malignant and 22 benign. SM detected 139/143 carcinomas (overall sensitivity: 97.2%) and was true negative in 19/22 benign lesions (overall specificity: 86.4%). SM sensitivity was 91% in ≤=10-mm carcinomas. SM was more accurate than Mx in 42/145 cases (29%), detecting cancer in 9 patients with Mx indeterminate for dense breasts (8/9 tumors were <10 mm), assessing additional tumor foci (all <10 mm) in 5 points with multifocal disease and correctly classifying 28 patients with inconclusive mammographic findings as affected by cancer or by benign disease. Mx was more accurate than SM in 3 patients, in each detecting 1 subcentimeter BC false negative on SM.
DBC planar SM seems a highly sensitive diagnostic tool in the detection of BC, even when small in size, and in the assessment of multifocal disease. A wider employment of this procedure is thus suggested, especially in indeterminate or inconclusive mammographic findings to improve sensitivity and specificity of Mx.

Item Type:Article
ID Code:6431
Status:Published
Refereed:Yes
Uncontrolled Keywords:Breast cancer, scintimammography, dedicated breast camera, Tc-99m tetrofosmin, mammography
Subjects:Area 06 - Scienze mediche > MED/36 Diagnostica per immagini e radioterapia
Divisions:001 Università di Sassari > 03 Istituti > Scienze radiologiche
001 Università di Sassari > 03 Istituti > Clinica medica generale e terapia medica
Publisher:Lippincott Williams & Wilkins
ISSN:0363-9762
eISSN:1536-0229
Copyright Holders:© 2008 Lippincott Williams & Wilkins
Deposited On:31 Aug 2011 10:04

I documenti depositati in UnissResearch sono protetti dalle leggi che regolano il diritto d'autore

Repository Staff Only: item control page