A Novel multithreshold method for nodule detection in lung CT

Golosio, Bruno and Masala, Giovanni Luca Christian and Piccioli, Alessio and Oliva, Piernicola and Carpinelli, Massimo and Cataldo, Rossella and Cerello, Piergiorgio and De Carlo, Francesco and Gargano, Gianfranco and Falaschi, Fabio and Kasae, Parnian and Torsello, Massimo (2009) A Novel multithreshold method for nodule detection in lung CT. Medical Physics, Vol. 36 (8), p. 3607-3618. ISSN 0094-2405. Article.

Full text not available from this repository.

DOI: 10.1118/1.3160107

Abstract

Multislice computed tomography (MSCT) is a valuable tool for lung cancer detection, thanks to its ability to identify noncalcified nodules of small size (from about 3 mm). Due to the large number of images generated by MSCT, there is much interest in developing computer-aided detection (CAD) systems that could assist radiologists in the lung nodule detection task. A complete multistage CAD system, including lung boundary segmentation, regions of interest (ROIs) selection, feature extraction, and false positive reduction is presented. The selection of ROIs is based on a multithreshold surface-triangulation approach. Surface triangulation is performed at different threshold values, varying from a minimum to a maximum value in a wide range. At a given threshold value, a ROI is defined as the volume inside a connected component of the triangulated isosurface. The evolution of a ROI as a function of the threshold can be represented by a treelike structure. A multithreshold ROI is defined as a path on this tree, which starts from a terminal ROI and ends on the root ROI. For each ROI, the volume, surface area, roundness, density, and moments of inertia are computed as functions of the threshold and used as input to a classification system based on artificial neural networks. The method is suitable to detect different types of nodules, including juxta-pleural nodules and nodules connected to blood vessels. A training set of 109 low-dose MSCT scans made available by the Pisa center of the Italung-CT trial and annotated by expert radiologists was used for the algorithm design and optimization. The system performance was tested on an independent set of 23 low-dose MSCT scans coming from the Pisa Italung-CT center and on 83 scans made available by the Lung Image Database Consortium (LIDC) annotated by four expert radiologists. On the Italung-CT test set, for nodules having a diameter greater than or equal to 3 mm, the system achieved 84% and 71% sensitivity at false positive/scan rates of 10 and 4, respectively. For nodules having a diameter greater than or equal to 4 mm, the sensitivities were 97% and 80% at false positive/scan rates of 10 and 4, respectively. On the LIDC data set, the system achieved a 79% sensitivity at a false positive/scan rate of 4 in the detection of nodules with a diameter greater than or equal to 3 mm that have been annotated by all four radiologists.

Item Type:Article
ID Code:4476
Status:Published
Refereed:Yes
Uncontrolled Keywords:Cancer, computerised tomography, feature extraction, lung, medical image processing, computer-aided diagnosis (CAD), image processing, computed tomography (CT), image segmentation
Subjects:Area 02 - Scienze fisiche > FIS/07 Fisica applicata (a beni culturali, ambientali, biologia e medicina)
Divisions:001 Università di Sassari > 03 Istituti > Matematica e fisica
Publisher:American Association of Physicists in Medicine
ISSN:0094-2405
Deposited On:02 Sep 2010 12:46