titoli, abstracts, parole chiave >>>
Clinical evaluation of the efficacy of one self-adhesive composite in dental hypersensitivity

Pinna, Roberto and Bortone, Antonella and Sotgiu, Giovanni and Dore, Stefano and Usai, Paolo and Milia, Egle Patrizia (2015) Clinical evaluation of the efficacy of one self-adhesive composite in dental hypersensitivity. Clinical Oral Investigations (in press). eISSN 1436-3771. Article.

Full text not available from this repository.

DOI: 10.1007/s00784-014-1390-3

Abstract

Objectives: The aim of the present study was to investigate the clinical effectiveness over 12 weeks of Vertise Flow, a self-adhering composite, in dental hypersensitivity (DH).
Material and methods: The study was conducted as a split-mouth randomized clinical trial. Vertise Flow was compared to the following: (1) Universal Dentine Sealant, (2) Clearfil Protect Bond, and (3) Flor-Opal ® Varnish. A total of 46 patients with 116 hypersensitive teeth were studied. Pain experience was generated by a cold stimulus and assessed using the visual analog scale (VAS) of pain. The response was recorded before the application of the materials (pre-1), immediately after (post-1), at 1- (post-2), 2- (post-3), and 12-week controls (post-4). Statistical differences in VAS were performed using the Kruskal–Wallis analysis at the different time-points (P  < 0.05), adjusting statistical significances for multiple comparisons (Bonferroni correction).
Results: All the materials showed any statistically significant differences at the baseline. After the application of each material, a VAS decrease was demonstrated at every post-control. VF showed significant hypersensitivity reduction in post-1. Statistically significant relief was also observed in post-2 while no significant differences were detected in post-3 and post-4.
Conclusions: After 12-week controls, there was no statistically significant hypersensitivity reduction using VF in respect to the other materials. On the other hand, any significant differences were detected in the decrease of the VAS irrespective of the desensitizing agent employed at the 12-week controls.
Clinical relevance: The significant increase in VAS scores within the 12-weeks of environment suggested there is instability of VF when used as desensitizing agent.

Item Type:Article
ID Code:10945
Status:In Press
Refereed:Yes
Uncontrolled Keywords:Dentine hypersensitivity, vertise flow, self-adhering composite, desensitizing agents
Subjects:Area 06 - Scienze mediche > MED/28 Malattie odontostomatologiche
Area 06 - Scienze mediche > MED/30 Malattie apparato visivo
Area 06 - Scienze mediche > MED/01 Statistica medica
Divisions:001 Università di Sassari > 01-a Nuovi Dipartimenti dal 2012 > Scienze Chirurgiche, Microchirurgiche e Mediche
001 Università di Sassari > 01-a Nuovi Dipartimenti dal 2012 > Scienze Biomediche
Publisher:Springer Berlin / Heildelberg
eISSN:1436-3771
Deposited On:26 May 2015 12:15

I documenti depositati in UnissResearch sono protetti dalle leggi che regolano il diritto d'autore

Repository Staff Only: item control page